How big is a run on a Macerator pump?

AMP FUSE WIRE SIZE PER FEET OF RUN* VOLTAGE DRAW SIZE 0’-10’ 10’-15’ 15’-25’ 25’-40’ 40’-60’ 12 Vdc 16 20 #16(1.5) #14(2.5) #14(2.5) #12(4) #6(16) 24 Vdc 8 15 #18(1) #16(1.5) #16(1.5) #14(2.5) #10(6) * Length of run is total length of the circuit from the power source to product and back to ground.

What to do if your Macerator pump stops working?

A service engineer can fix this for you by removing the foreign object from the blade manually removing the object and by turning the pliers counterclockwise. If the macerator pump keeps starting by itself, then it is potentially a problem with the microswitch.

How does a self priming Macerator pump work?

The macerator section grinds waste down to a particle size of 1/8″ (3mm) maximum so it can easily by pumped through a 1″ (19mm) ID discharge hose. The pump section is self-priming, permitting the unit to be mounted above the tank in a convenient location.

Why does my Macerator stop working when I flush the toilet?

If your macerator is foaming out of the air vent then it is due to the over use of toilet cleaner or bleach being used. If this continues for a long period of time, then the motor will stop working because it is overheated this is because the toilet pump cannot pump water out correctly.

What happens if the Fuse goes off on a Macerator?

If you are lucky, the macerator will be blocked with unwanted item or a switch has been accidentally knocked off or maybe the fuse as gone. If the fuse has gone it is always good to investigate the reason, as the motor may be on its way out or there is a general fault with the machine.

AMP FUSE WIRE SIZE PER FEET OF RUN* VOLTAGE DRAW SIZE 0’-10’ 10’-15’ 15’-25’ 25’-40’ 40’-60’ 12 Vdc 16 20 #16(1.5) #14(2.5) #14(2.5) #12(4) #6(16) 24 Vdc 8 15 #18(1) #16(1.5) #16(1.5) #14(2.5) #10(6) * Length of run is total length of the circuit from the power source to product and back to ground.

Why does my Macerator keep running even when the pump is turned off?

One common problem that our customers have is that their macerator toilet keeps running even when turned off. This problem is caused when the pump has already flushed and continues to do so even though the macerator is clear. There are a number of reasons why this might occur: Blocked macerator or pump

When to use a self priming Macerator pump?

SPECIFICATION Priming- 5ft When Wet 4ft When Dry hEAD CAPACITy AND FLOW RATES reduce the possibility of a continued build up of sediment AMPS Head Ft Meters GPM Liters 12 Volt 24 Volt 0 0 12.5 47 14.0 7.6 5 1.5 11.5 44 14.5 7.8 10 3 10.5 40 15.0 8.1 15 4.5 9.0 34 16.0 8.6 20 6 7.5 28 16.5 8.9